Vulnerability in Emerson Dl8000 Firmware
CVE-2022-30264
The Emerson ROC and FloBoss RTU product lines through 2022-05-02 perform insecure filesystem operations. They utilize the ROC protocol (4000/TCP, 5000/TCP) for communications between a master terminal and RTUs. Opcode 203 of this protocol allows a master terminal to transfer files to and from the flash filesystem and carrying out arbitrary file and directory read, write, and delete operations.
Published · last modified .
CVSS v3 metric
CVSS v3 base score 9.8 (Critical). Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H.
EPSS exploit prediction
EPSS 0.005, 46.5th percentile (scored ); unchanged over 30 days. About EPSS.
Affected products
Weakness classification (CWE)
Public exploits and proof-of-concept code
Also mentioned in 1 other repository (karimhabush/cyberowl). These reference the CVE in a list, notes or a scanner and are not exploit code for it.
References
- www.forescout.com/blog/ (Third Party Advisory)
- www.cisa.gov/uscert/ics/advisories/icsa-22-223-04 (US Government Resource, Third Party Advisory, Mitigation)