SQL Injection in Philips Tasy Electronic Medical Record
CVE-2021-39376
Philips Healthcare Tasy Electronic Medical Record (EMR) 3.06 allows SQL injection via the CorCad_F2/executaConsultaEspecifico IE_CORPO_ASSIST or CD_USUARIO_CONVENIO parameter.
Vulnerability class: SQL Injection
Published · last modified .
CVSS v3 metric
CVSS v3 base score 8.8 (High). Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H.
EPSS exploit prediction
EPSS: 0.013 (68.2th percentile), scored .
Low probability of exploitation in the next 30 days, but still tracked. 68th percentile — 68.2% of CVEs in the catalogue have a lower EPSS than this one. How to read EPSS.
EPSS over last 30 days · oldest: 0.013 · newest: 0.013 · change: 0.000
Affected products
- Philips Tasy Electronic Medical Record — versions 3.06
Weakness classification (CWE)
References
- diesec.home.blog/2021/08/24/philips-tasy-emr-3-06-sql-injection-cve-2021-39375c… (Exploit, Third Party Advisory)
Frequently asked questions
- What is CVE-2021-39376?
- CVE-2021-39376 is a high-severity vulnerability in Philips Tasy Electronic Medical Record, classified under SQL Injection. CVSS score: 8.8/10. Published 2021-08-24.
- How severe is CVE-2021-39376?
- High severity. CVSS v3 base score is 8.8 out of 10.