Vulnerability in Logitech S120
CVE-2021-38547
Logitech Z120 and S120 speakers through 2021-08-09 allow remote attackers to recover speech signals from an LED on the device, via a telescope and an electro-optical sensor, aka a "Glowworm" attack. The power indicator LED of the speakers is connected directly to the power line, as a result, the intensity of a device's power indicator LED is correlative to the power consumption. The sound played by the speakers affects their power consumption and as a result is also correlative to the light intensity of the LEDs. By analyzing measurements obtained from an electro-optical sensor directed at the power indicator LEDs of the speakers, we can recover the sound played by them.
Published · last modified .
CVSS v3 metric
CVSS v3 base score 5.9 (Medium). Vector: CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N.
EPSS exploit prediction
EPSS: 0.013 (70.3th percentile), scored .
Low probability of exploitation in the next 30 days, but still tracked. 70th percentile — 70.3% of CVEs in the catalogue have a lower EPSS than this one. How to read EPSS.
EPSS over last 30 days · oldest: 0.013 · newest: 0.013 · change: 0.000
Affected products
References
- www.nassiben.com/glowworm-attack (Exploit, Third Party Advisory)
Frequently asked questions
- What is CVE-2021-38547?
- CVE-2021-38547 is a medium-severity vulnerability in Logitech S120. CVSS score: 5.9/10. Published 2021-08-11.
- How severe is CVE-2021-38547?
- Medium severity. CVSS v3 base score is 5.9 out of 10.