CVE Explore

Improper input validation in Siemens Sinamics Sl150 Firmware

CVE-2021-27388

CVSS v3
9.8 Critical
Public exploits
None known
EPSS
0.015 · 75.6th percentile
Published
2021-06-15

SINAMICS medium voltage routable products are affected by a vulnerability in the Sm@rtServer component for remote access that could allow an unauthenticated attacker to cause a denial-of-service condition, and/or execution of limited configuration modifications and/or execution of limited control commands on the SINAMICS Medium Voltage Products, Remote Access (SINAMICS SL150: All versions, SINAMICS SM150: All versions, SINAMICS SM150i: All versions).

Published · last modified .

CVSS v3 metric

CVSS v3 base score 9.8 (Critical). Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H.

Attack Vector
Network AV:N
Attack Complexity
Low AC:L
Privileges Required
None PR:N
User Interaction
None UI:N
Scope
Unchanged S:U
Confidentiality
High C:H
Integrity
High I:H
Availability
High A:H

EPSS exploit prediction

EPSS 0.015, 75.6th percentile (last changed ); unchanged over 30 days. About EPSS.

Affected products

Weakness classification (CWE)

References