Resource exhaustion in Siemens Scalance W740 Firmware
CVE-2021-25666
- CVSS v3
- 4.3 Medium
- Public exploits
- None known
- EPSS
- 0.007 · 54.0th percentile
- Published
- 2021-02-09
A vulnerability has been identified in SCALANCE W780 and W740 (IEEE 802.11n) family (All versions < V6.3). Sending specially crafted packets through the ARP protocol to an affected device could cause a partial denial-of-service, preventing the device to operate normally for a short period of time.
Published · last modified .
CVSS v3 metric
CVSS v3 base score 4.3 (Medium). Vector: CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L.
- Attack Vector
- Adjacent
AV:A - Attack Complexity
- Low
AC:L - Privileges Required
- None
PR:N - User Interaction
- None
UI:N - Scope
- Unchanged
S:U - Confidentiality
- None
C:N - Integrity
- None
I:N - Availability
- Low
A:L
EPSS exploit prediction
EPSS 0.007, 54.0th percentile (last changed ); unchanged over 30 days. About EPSS.
Affected products
- Siemens Scalance W740 Firmware
- Siemens Scalance W780 And W740 (Ieee 802.11n) Family — versions All versions < V6.3
- Siemens Scalance W780 Firmware
Weakness classification (CWE)
References
- cert-portal.siemens.com/productcert/pdf/ssa-686152.pdf (Vendor Advisory)
- us-cert.cisa.gov/ics/advisories/icsa-21-040-07 (VDB Entry, Third Party Advisory)