Use After Free in Schneider-Electric Guicon
CVE-2021-22808
- CVSS v3
- 7.8 High
- Public exploits
- None known
- EPSS
- 0.009 · 58.9th percentile
- Published
- 2022-01-28
A CWE-416: Use After Free vulnerability exists that could cause arbitrary code execution when a malicious *.gd1 configuration file is loaded into the GUIcon tool. Affected Product: Eurotherm by Schneider Electric GUIcon Version 2.0 (Build 683.003) and prior
Vulnerability class: Use-After-Free
Published · last modified .
CVSS v3 metric
CVSS v3 base score 7.8 (High). Vector: CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H.
- Attack Vector
- Local
AV:L - Attack Complexity
- Low
AC:L - Privileges Required
- None
PR:N - User Interaction
- Required
UI:R - Scope
- Unchanged
S:U - Confidentiality
- High
C:H - Integrity
- High
I:H - Availability
- High
A:H
EPSS exploit prediction
EPSS 0.009, 58.9th percentile (last changed ); unchanged over 30 days. About EPSS.
Affected products
Weakness classification (CWE)
References
- download.schneider-electric.com/files (Vendor Advisory)