Path Traversal in Schneider-Electric Ecostruxure Machine Expert
CVE-2021-22704
- CVSS v3
- 9.1 Critical
- Public exploits
- None known
- EPSS
- 0.013 · 70.6th percentile
- Published
- 2021-09-02
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists in Harmony/HMI Products Configured by Vijeo Designer (all versions prior to V6.2 SP11 ), Vijeo Designer Basic (all versions prior to V1.2), or EcoStruxure Machine Expert (all versions prior to V2.0) that could cause a Denial of Service or unauthorized access to system information when connecting to the Harmony HMI over FTP.
Vulnerability class: Path Traversal (Directory Traversal)
Published · last modified .
CVSS v3 metric
CVSS v3 base score 9.1 (Critical). Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H.
- Attack Vector
- Network
AV:N - Attack Complexity
- Low
AC:L - Privileges Required
- None
PR:N - User Interaction
- None
UI:N - Scope
- Unchanged
S:U - Confidentiality
- High
C:H - Integrity
- None
I:N - Availability
- High
A:H
EPSS exploit prediction
EPSS 0.013, 70.6th percentile (last changed ); unchanged over 30 days. About EPSS.
Affected products
- Schneider-Electric Ecostruxure Machine Expert — versions 2.0
- Schneider-Electric Vijeo Designer
- Harmony/hmi Products Configured By Vijeo Designer (All Versions Prior To V6.2 Sp11 ), Basic V1.2), Or Ecostruxure Machine Expert V2.0) — versions Harmony/HMI Products Configured by Vijeo Designer (all versions prior to V6.2 SP11 ), Vijeo Designer Basic (all versions prior to V1.2), or EcoStruxure Machine Expert (all versions prior to V2.0)
Weakness classification (CWE)
References
- download.schneider-electric.com/files (Vendor Advisory)