Path Traversal in Schneider-Electric Ecostruxure Machine Expert

CVE-2021-22704

CVSS v3
9.1 Critical
Public exploits
None known
EPSS
0.013 · 70.6th percentile
Published
2021-09-02

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists in Harmony/HMI Products Configured by Vijeo Designer (all versions prior to V6.2 SP11 ), Vijeo Designer Basic (all versions prior to V1.2), or EcoStruxure Machine Expert (all versions prior to V2.0) that could cause a Denial of Service or unauthorized access to system information when connecting to the Harmony HMI over FTP.

Vulnerability class: Path Traversal (Directory Traversal)

Published · last modified .

CVSS v3 metric

CVSS v3 base score 9.1 (Critical). Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H.

Attack Vector
Network AV:N
Attack Complexity
Low AC:L
Privileges Required
None PR:N
User Interaction
None UI:N
Scope
Unchanged S:U
Confidentiality
High C:H
Integrity
None I:N
Availability
High A:H

EPSS exploit prediction

EPSS 0.013, 70.6th percentile (last changed ); unchanged over 30 days. About EPSS.

Affected products

  • Schneider-Electric Ecostruxure Machine Expert — versions 2.0
  • Schneider-Electric Vijeo Designer
  • Harmony/hmi Products Configured By Vijeo Designer (All Versions Prior To V6.2 Sp11 ), Basic V1.2), Or Ecostruxure Machine Expert V2.0) — versions Harmony/HMI Products Configured by Vijeo Designer (all versions prior to V6.2 SP11 ), Vijeo Designer Basic (all versions prior to V1.2), or EcoStruxure Machine Expert (all versions prior to V2.0)

Weakness classification (CWE)

References