Information disclosure in Abb Mybuildings

CVE-2021-22272

The vulnerability origins in the commissioning process where an attacker of the ControlTouch can enter a serial number in a specific way to transfer the device virtually into her/his my.busch-jaeger.de or mybuildings.abb.com profile. A successful attacker can observe and control a ControlTouch remotely under very specific circumstances. The issue is fixed in the cloud side of the system. No firmware update is needed for customer products. If a user wants to understand if (s)he is affected, please read the advisory. This issue affects: ABB and Busch-Jaeger, ControlTouch

Vulnerability class: Information Disclosure

Published · last modified .

CVSS v3 metric

CVSS v3 base score 6.5 (Medium). Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N.

EPSS exploit prediction

EPSS: 0.007 (49.5th percentile), scored .

Very low probability of exploitation in the next 30 days; routine patching cadence is appropriate. 49th percentile — 49.5% of CVEs in the catalogue have a lower EPSS than this one. How to read EPSS.

EPSS trend (30 days)EPSS over the last 30 days for CVE-2021-22272: held from 0.007 to 0.007.

EPSS over last 30 days · oldest: 0.007 · newest: 0.007 · change: 0.000

Affected products

Weakness classification (CWE)

References

Frequently asked questions

What is CVE-2021-22272?
CVE-2021-22272 is a medium-severity vulnerability in Abb Mybuildings, classified under Information Disclosure. CVSS score: 6.5/10. Published 2021-09-27.
How severe is CVE-2021-22272?
Medium severity. CVSS v3 base score is 6.5 out of 10.