CVE Explore

Vulnerability in Schneider-Electric Gp-Pro Ex Firmware

CVE-2020-7492

CVSS v3
6.5 Medium
Public exploits
None known
EPSS
0.012 · 68.0th percentile
Published
2020-06-16

A CWE-521: Weak Password Requirements vulnerability exists in the GP-Pro EX V1.00 to V4.09.100 which could cause the discovery of the password when the user is entering the password because it is not masqueraded.

Published · last modified .

CVSS v3 metric

CVSS v3 base score 6.5 (Medium). Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N.

Attack Vector
Network AV:N
Attack Complexity
Low AC:L
Privileges Required
None PR:N
User Interaction
Required UI:R
Scope
Unchanged S:U
Confidentiality
High C:H
Integrity
None I:N
Availability
None A:N

EPSS exploit prediction

EPSS 0.012, 68.0th percentile (last changed ); unchanged over 30 days. About EPSS.

Affected products

Weakness classification (CWE)

References