Vulnerability in Bosch Monitor Wall

CVE-2020-6789

Loading a DLL through an Uncontrolled Search Path Element in the Bosch Monitor Wall installer up to and including version 10.00.0164 potentially allows an attacker to execute arbitrary code on a victim's system. A prerequisite is that the victim is tricked into placing a malicious DLL in the same directory where the installer is started from.

Published · last modified .

CVSS v3 metric

CVSS v3 base score 7.8 (High). Vector: CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H.

EPSS exploit prediction

EPSS: 0.003 (25.7th percentile), scored .

Very low probability of exploitation in the next 30 days; routine patching cadence is appropriate. 26th percentile — 25.7% of CVEs in the catalogue have a lower EPSS than this one. How to read EPSS.

EPSS trend (30 days)EPSS over the last 30 days for CVE-2020-6789: held from 0.003 to 0.003.

EPSS over last 30 days · oldest: 0.003 · newest: 0.003 · change: 0.000

Affected products

Weakness classification (CWE)

Public proof-of-concept exploits

References

Frequently asked questions

What is CVE-2020-6789?
CVE-2020-6789 is a high-severity vulnerability in Bosch Monitor Wall, classified under Uncontrolled Search Path Element. CVSS score: 7.8/10. Published 2021-03-25.
How severe is CVE-2020-6789?
High severity. CVSS v3 base score is 7.8 out of 10.
Is CVE-2020-6789 known to be exploited?
1 public proof-of-concept repositories are indexed. Not currently listed in the CISA KEV catalog.