Resource exhaustion in Rockwellautomation Factorytalk Linx
CVE-2020-5802
An attacker-controlled memory allocation size can be passed to the C++ new operator in RnaDaSvr.dll by sending a specially crafted ConfigureItems message to TCP port 4241. This will cause an unhandled exception, resulting in termination of RSLinxNG.exe. Observed in FactoryTalk 6.11. All versions of FactoryTalk Linx are affected.
Published · last modified .
CVSS v3 metric
CVSS v3 base score 7.5 (High). Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H.
EPSS exploit prediction
EPSS 0.447, 98.8th percentile (last changed ); unchanged over 30 days. About EPSS.
Affected products
- Rockwellautomation Factorytalk Linx
- Rockwell Factorytalk Linx — versions All versions of FactoryTalk Linx
Weakness classification (CWE)
References
- www.tenable.com/security/research/tra-2020-71 (Third Party Advisory)