Vulnerability in Rockwellautomation Factorytalk Linx
CVE-2020-5801
An attacker can craft and send an OpenNamespace message to port 4241 with valid session-id that triggers an unhandled exception in CFTLDManager::HandleRequest function in RnaDaSvr.dll, resulting in process termination. Observed in FactoryTalk Linx 6.11. All versions of FactoryTalk Linx are affected.
Published · last modified .
CVSS v3 metric
CVSS v3 base score 7.5 (High). Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H.
EPSS exploit prediction
EPSS 0.297, 98.2th percentile (last changed ); unchanged over 30 days. About EPSS.
Affected products
- Rockwellautomation Factorytalk Linx
- Rockwell Factorytalk Linx — versions All versions of FactoryTalk Linx
Weakness classification (CWE)
References
- www.tenable.com/security/research/tra-2020-71 (Third Party Advisory)