Auth bypass in Openclinic Project
CVE-2020-28937
OpenClinic version 0.8.2 is affected by a missing authentication vulnerability that allows unauthenticated users to access any patient's medical test results, possibly resulting in disclosure of Protected Health Information (PHI) stored in the application, via a direct request for the /tests/ URI.
Vulnerability class: Broken Authentication
Published · last modified .
CVSS v3 metric
CVSS v3 base score 7.5 (High). Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N.
EPSS exploit prediction
EPSS 0.013, 71.7th percentile (last changed ); unchanged over 30 days. About EPSS.
Affected products
- Openclinic Project — versions 0.8.2
Weakness classification (CWE)
References
- labs.bishopfox.com/advisories/openclinic-version-0.8.2 (Exploit, Third Party Advisory)