Vulnerability in Siemens Simatic Mv400 Family
CVE-2020-25241
A vulnerability has been identified in SIMATIC MV400 family (All Versions < V7.0.6). The underlying TCP stack of the affected products does not correctly validate the sequence number for incoming TCP RST packages. An attacker could exploit this to terminate arbitrary TCP sessions.
Published · last modified .
CVSS v3 metric
CVSS v3 base score 7.5 (High). Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H.
EPSS exploit prediction
EPSS 0.011, 65.4th percentile (last changed ); unchanged over 30 days. About EPSS.
Affected products
- Siemens Simatic Mv400 Family — versions All Versions < V7.0.6
- Siemens Simatic Mv420 Sr-B Body Firmware
- Siemens Simatic Mv420 Sr-B Firmware
- Siemens Simatic Mv420 Sr-P Body Firmware
- Siemens Simatic Mv420 Sr-P Firmware
- Siemens Simatic Mv440 Hr Firmware
- Siemens Simatic Mv440 Sr Firmware
- Siemens Simatic Mv440 Ur Firmware
Weakness classification (CWE)
References
- cert-portal.siemens.com/productcert/pdf/ssa-599268.pdf (Vendor Advisory)