Vulnerability in Rockwell Automation Isagraf Runtime
CVE-2020-25182
Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x searches for and loads DLLs as dynamic libraries. Uncontrolled loading of dynamic libraries could allow a local, unauthenticated attacker to execute arbitrary code. This vulnerability only affects ISaGRAF Runtime when running on Microsoft Windows systems.
Published · last modified .
CVSS v3 metric
CVSS v3 base score 6.7 (Medium). Vector: CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H.
EPSS exploit prediction
EPSS 0.004, 39.3th percentile (scored ); unchanged over 30 days. About EPSS.
Affected products
- Rockwell Automation Isagraf Runtime — versions 4.x, 5.x
- Rockwellautomation Aadvance Controller
- Rockwellautomation Isagraf Free Runtime
- Rockwellautomation Isagraf Runtime
- Rockwellautomation Micro810 Firmware
- Rockwellautomation Micro820 Firmware
- Rockwellautomation Micro830 Firmware
- Rockwellautomation Micro850 Firmware
- Rockwellautomation Micro870 Firmware
- Schneider-Electric Easergy C5 Firmware
Weakness classification (CWE)
References
- www.cisa.gov/uscert/ics/advisories/icsa-20-280-01 (US Government Resource, Third Party Advisory)
- rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1131699 (Vendor Advisory, Permissions Required)
- download.schneider-electric.com/files (Vendor Advisory)
- www.xylem.com/siteassets/about-xylem/cybersecurity/advisories/xylem-multismart-… (Vendor Advisory)