Vulnerability in Siemens Sicam Mmu Firmware
CVE-2020-10039
- CVSS v3
- 8.1 High
- Public exploits
- None known
- EPSS
- 0.005 · 45.0th percentile
- Published
- 2020-07-14
A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). An attacker in a privileged network position between a legitimate user and the web server might be able to conduct a Man-in-the-middle attack and gain read and write access to the transmitted data.
Published · last modified .
CVSS v3 metric
CVSS v3 base score 8.1 (High). Vector: CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H.
EPSS exploit prediction
EPSS 0.005, 45.0th percentile (last changed ); unchanged over 30 days. About EPSS.
Affected products
- Siemens Sicam Mmu Firmware
- Siemens Sicam Sgu Firmware
- Siemens Sicam T Firmware
- Siemens Ag Sicam Mmu — versions All versions < V2.05
- Siemens Ag Sicam Sgu — versions All versions
- Siemens Ag Sicam T — versions All versions < V2.18
Weakness classification (CWE)
References
- cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf (Vendor Advisory)