CVE Explore

XSS in Siemens Scalance S602

CVE-2019-6585

CVSS v3
6.1 Medium
Public exploits
None known
EPSS
0.007 · 55.2th percentile
Published
2020-03-10

A vulnerability has been identified in SCALANCE S602 (All versions >= V3.0 and < V4.1), SCALANCE S612 (All versions >= V3.0 and < V4.1), SCALANCE S623 (All versions >= V3.0 and < V4.1), SCALANCE S627-2M (All versions >= V3.0 and < V4.1). The integrated configuration web server of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed.

Published · last modified .

CVSS v3 metric

CVSS v3 base score 6.1 (Medium). Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N.

Attack Vector
Network AV:N
Attack Complexity
Low AC:L
Privileges Required
None PR:N
User Interaction
Required UI:R
Scope
Changed S:C
Confidentiality
Low C:L
Integrity
Low I:L
Availability
None A:N

EPSS exploit prediction

EPSS 0.007, 55.2th percentile (last changed ); unchanged over 30 days. About EPSS.