SQL Injection in Siemens Control Center Server (Ccs)
CVE-2019-19292
A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The Control Center Server (CCS) contains an SQL injection vulnerability in its XML-based communication protocol as provided by default on ports 5444/tcp and 5440/tcp. An authenticated remote attacker could exploit this vulnerability to read or modify the CCS database and potentially execute administrative database operations or operating system commands.
Vulnerability class: SQL Injection
Published · last modified .
CVSS v3 metric
CVSS v3 base score 8.8 (High). Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H.
EPSS exploit prediction
EPSS: 0.020 (80.4th percentile), scored .
Low probability of exploitation in the next 30 days, but still tracked. 80th percentile — 80.4% of CVEs in the catalogue have a lower EPSS than this one. How to read EPSS.
EPSS over last 30 days · oldest: 0.020 · newest: 0.020 · change: 0.000
Affected products
- Siemens Control Center Server (Ccs) — versions All versions < V1.5.0
- Siemens Sinvr 3 Central Control Server
- Siemens Sinvr 3 Video Server
Weakness classification (CWE)
References
- cert-portal.siemens.com/productcert/pdf/ssa-844761.pdf (Mitigation, Vendor Advisory)
- cert-portal.siemens.com/productcert/pdf/ssa-761844.pdf
Frequently asked questions
- What is CVE-2019-19292?
- CVE-2019-19292 is a high-severity vulnerability in Siemens Control Center Server (Ccs), classified under SQL Injection. CVSS score: 8.8/10. Published 2020-03-10.
- How severe is CVE-2019-19292?
- High severity. CVSS v3 base score is 8.8 out of 10.