Path Traversal in Siemens Control Center Server (Ccs)
CVE-2019-19290
A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The DOWNLOADS section in the web interface of the Control Center Server (CCS) contains a path traversal vulnerability that could allow an authenticated remote attacker to access and download arbitrary files from the server where CCS is installed.
Vulnerability class: Path Traversal (Directory Traversal)
Published · last modified .
CVSS v3 metric
CVSS v3 base score 6.5 (Medium). Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N.
EPSS exploit prediction
EPSS: 0.018 (78.0th percentile), scored .
Low probability of exploitation in the next 30 days, but still tracked. 78th percentile — 78.0% of CVEs in the catalogue have a lower EPSS than this one. How to read EPSS.
EPSS over last 30 days · oldest: 0.018 · newest: 0.018 · change: 0.000
Affected products
- Siemens Control Center Server (Ccs) — versions All versions < V1.5.0
- Siemens Sinvr 3 Central Control Server
- Siemens Sinvr 3 Video Server
Weakness classification (CWE)
References
- cert-portal.siemens.com/productcert/pdf/ssa-844761.pdf (Mitigation, Vendor Advisory)
- cert-portal.siemens.com/productcert/pdf/ssa-761844.pdf
Frequently asked questions
- What is CVE-2019-19290?
- CVE-2019-19290 is a medium-severity vulnerability in Siemens Control Center Server (Ccs), classified under Path Traversal. CVSS score: 6.5/10. Published 2020-03-10.
- How severe is CVE-2019-19290?
- Medium severity. CVSS v3 base score is 6.5 out of 10.