Auth bypass in Siemens Sinvr 3 Central Control Server

CVE-2019-18339

A vulnerability has been identified in SiNVR/SiVMS Video Server (All versions < V5.0.0). The HTTP service (default port 5401/tcp) of the SiVMS/SiNVR Video Server contains an authentication bypass vulnerability, even when properly configured with enforced authentication. A remote attacker with network access to the Video Server could exploit this vulnerability to read the SiVMS/SiNVR users database, including the passwords of all users in obfuscated cleartext.

Vulnerability class: Broken Authentication

Published · last modified .

CVSS v3 metric

CVSS v3 base score 9.8 (Critical). Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H.

EPSS exploit prediction

EPSS: 0.027 (85.2th percentile), scored .

Low probability of exploitation in the next 30 days, but still tracked. 85th percentile — 85.2% of CVEs in the catalogue have a lower EPSS than this one. How to read EPSS.

EPSS trend (30 days)EPSS over the last 30 days for CVE-2019-18339: held from 0.027 to 0.027.

EPSS over last 30 days · oldest: 0.027 · newest: 0.027 · change: 0.000

Affected products

Weakness classification (CWE)

References

Frequently asked questions

What is CVE-2019-18339?
CVE-2019-18339 is a critical-severity vulnerability in Siemens Sinvr 3 Central Control Server, classified under Missing Authentication for Critical Function. CVSS score: 9.8/10. Published 2019-12-12.
How severe is CVE-2019-18339?
Critical severity. CVSS v3 base score is 9.8 out of 10.