Auth bypass in Siemens Sppa-T3000 Application Server
CVE-2019-18332
- CVSS v3
- 5.3 Medium
- Public exploits
- None known
- EPSS
- 0.010 · 63.3th percentile
- Published
- 2019-12-12
A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server could gain access to directory listings of the server by sending specifically crafted packets to 80/tcp, 8095/tcp or 8080/tcp. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
Vulnerability class: Information Disclosure
Published · last modified .
CVSS v3 metric
CVSS v3 base score 5.3 (Medium). Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N.
EPSS exploit prediction
EPSS 0.010, 63.3th percentile (last changed ); unchanged over 30 days. About EPSS.
Affected products
- Siemens Sppa-T3000 Application Server — versions All versions < Service Pack R8.2 SP2
- Siemens Sppa-T3000 Application Server — versions r8.2
Weakness classification (CWE)
References
- cert-portal.siemens.com/productcert/pdf/ssa-451445.pdf (Mitigation, Vendor Advisory)