Vulnerability in Siemens S7-200 Smart
CVE-2019-13945
A vulnerability has been identified in SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-1200 CPU family < V4.x (incl. SIPLUS variants) (All versions), SIMATIC S7-1200 CPU family V4.x (incl. SIPLUS variants) (All versions with Function State (FS) < 11), SIMATIC S7-200 SMART CPU CR20s (6ES7 288-1CR20-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU CR30s (6ES7 288-1CR30-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU CR40 (6ES7 288-1CR40-0AA0) (All versions <= V2.2.2 and Function State (FS) <= 8), SIMATIC S7-200 SMART CPU CR40s (6ES7 288-1CR40-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU CR60 (6ES7 288-1CR60-0AA0) (All versions <= V2.2.2 and Function State (FS) <= 10), SIMATIC S7-200 SMART CPU CR60s (6ES7 288-1CR60-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU SR20 (6ES7 288-1SR20-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 11), SIMATIC S7-200 SMART CPU SR30 (6ES7 288-1SR30-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 10), SIMATIC S7-200 SMART CPU SR40 (6ES7 288-1SR40-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 10), SIMATIC S7-200 SMART CPU SR60 (6ES7 288-1SR60-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 12), SIMATIC S7-200 SMART CPU ST20 (6ES7 288-1ST20-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 9), SIMATIC S7-200 SMART CPU ST30 (6ES7 288-1ST30-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 9), SIMATIC S7-200 SMART CPU ST40 (6ES7 288-1ST40-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 8), SIMATIC S7-200 SMART CPU ST60 (6ES7 288-1ST60-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 8), SIMATIC S7-200 SMART CPU family (All versions). There is an access mode used during manufacturing of the affected devices that allows additional diagnostic functionality. The security vulnerability could be exploited by an attacker with physical access to the UART interface during boot process.
EPSS: 0.005 (43.0th percentile) — read the EPSS interpretation.
CVSS v3 metric
CVSS v3 base score 6.8 (Medium). Vector: CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H.
Affected products
- Siemens S7-200_smart
- Siemens S7-200_smart_firmware
- Siemens Simatic_s7-1200
- Siemens Simatic_s7-1200_firmware
- Siemens Simatic_s7-200_smart_cpu_cr20s
- Siemens Simatic_s7-200_smart_cpu_cr20s_firmware
- Siemens Simatic_s7-200_smart_cpu_cr30s
- Siemens Simatic_s7-200_smart_cpu_cr30s_firmware
- Siemens Simatic_s7-200_smart_cpu_cr40
- Siemens Simatic_s7-200_smart_cpu_cr40_firmware
Weakness classification (CWE)
Public proof-of-concept exploits
References
- productcert@siemens.com (x_refsource_MISC, Vendor Advisory)
Frequently asked questions
- What is CVE-2019-13945?
- CVE-2019-13945 is a medium-severity vulnerability in Siemens S7-200 Smart, classified under CWE-749. CVSS score: 6.8/10. Published 2019-12-12.
- How severe is CVE-2019-13945?
- Medium severity. CVSS v3 base score is 6.8 out of 10.
- Is CVE-2019-13945 known to be exploited?
- 2 public proof-of-concept repositories are indexed. Not currently listed in the CISA KEV catalog.