Resource exhaustion in Siemens Scalance S602

CVE-2019-13926

A vulnerability has been identified in SCALANCE S602 (All versions >= V3.0 and < V4.1), SCALANCE S612 (All versions >= V3.0 and < V4.1), SCALANCE S623 (All versions >= V3.0 and < V4.1), SCALANCE S627-2M (All versions >= V3.0 and < V4.1). Specially crafted packets sent to port 443/tcp of affected devices could cause a Denial-of-Service condition of the web server. A cold reboot is required to restore the functionality of the device.

Vulnerability class: DoS (Denial of Service)

Published · last modified .

CVSS v3 metric

CVSS v3 base score 7.5 (High). Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H.

EPSS exploit prediction

EPSS: 0.015 (73.3th percentile), scored .

Low probability of exploitation in the next 30 days, but still tracked. 73rd percentile — 73.3% of CVEs in the catalogue have a lower EPSS than this one. How to read EPSS.

EPSS trend (30 days)EPSS over the last 30 days for CVE-2019-13926: held from 0.015 to 0.015.

EPSS over last 30 days · oldest: 0.015 · newest: 0.015 · change: 0.000

Affected products

Weakness classification (CWE)

References

Frequently asked questions

What is CVE-2019-13926?
CVE-2019-13926 is a high-severity vulnerability in Siemens Scalance S602, classified under Uncontrolled Resource Consumption. CVSS score: 7.5/10. Published 2020-02-11.
How severe is CVE-2019-13926?
High severity. CVSS v3 base score is 7.5 out of 10.