Improper input validation in Siemens Siclock Tc100 Firmware
CVE-2018-4851
- CVSS v3
- 8.2 High
- Public exploits
- None known
- EPSS
- 0.014 · 73.0th percentile
- Published
- 2018-07-03
A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). An attacker with network access to the device could cause a Denial-of-Service condition by sending certain packets to the device, causing potential reboots of the device. The core functionality of the device could be impacted. The time serving functionality recovers when time synchronization with GPS devices or other NTP servers are completed.
Published · last modified .
CVSS v3 metric
CVSS v3 base score 8.2 (High). Vector: CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H.
- Attack Vector
- Network
AV:N - Attack Complexity
- Low
AC:L - Privileges Required
- None
PR:N - User Interaction
- None
UI:N - Scope
- Unchanged
S:U - Confidentiality
- None
C:N - Integrity
- Low
I:L - Availability
- High
A:H
EPSS exploit prediction
EPSS 0.014, 73.0th percentile (last changed ); unchanged over 30 days. About EPSS.
Affected products
- Siemens Siclock Tc100 Firmware
- Siemens Siclock Tc400 Firmware
- Siemens Ag Siclock Tc100, Tc400 — versions SICLOCK TC100 : All versions, SICLOCK TC400 : All versions
Weakness classification (CWE)
References
- www.securityfocus.com/bid/104672 (Third Party Advisory, VDB Entry, vdb-entry)
- cert-portal.siemens.com/productcert/pdf/ssa-197012.pdf (Mitigation, Vendor Advisory)