CVE Explore

XSS in Siemens Scalance X-200 Firmware

CVE-2018-4848

CVSS v3
6.1 Medium
Public exploits
None known
EPSS
0.010 · 63.0th percentile
Published
2018-06-14

A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.3), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.4.1), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.3). The integrated configuration web server of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed. At the stage of publishing this security advisory no public exploitation is known. The vendor has confirmed the vulnerability and provides mitigations to resolve it.

Published · last modified .

CVSS v3 metric

CVSS v3 base score 6.1 (Medium). Vector: CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N.

Attack Vector
Network AV:N
Attack Complexity
Low AC:L
Privileges Required
None PR:N
User Interaction
Required UI:R
Scope
Changed S:C
Confidentiality
Low C:L
Integrity
Low I:L
Availability
None A:N

EPSS exploit prediction

EPSS 0.010, 63.0th percentile (last changed ); unchanged over 30 days. About EPSS.

Affected products

Weakness classification (CWE)

References