XSS in Siemens Scalance X200

CVE-2018-4842

A vulnerability has been identified in SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.4.1), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.3). A remote, authenticated attacker with access to the configuration web server could be able to store script code on the web site, if the HRP redundancy option is set. This code could be executed in the web browser of victims visiting this web site (XSS), affecting its confidentiality, integrity and availability. User interaction is required for successful exploitation, as the user needs to visit the manipulated web site. At the stage of publishing this security advisory no public exploitation is known. The vendor has confirmed the vulnerability and provides mitigations to resolve it.

Vulnerability class: XSS (Cross-Site Scripting)

EPSS: 0.008 (53.8th percentile) — read the EPSS interpretation.

CVSS v3 metric

CVSS v3 base score 4.8 (Medium). Vector: CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N.

Affected products

Weakness classification (CWE)

References

Frequently asked questions

What is CVE-2018-4842?
CVE-2018-4842 is a medium-severity vulnerability in Siemens Scalance X200, classified under Cross-site Scripting. CVSS score: 4.8/10. Published 2018-06-14.
How severe is CVE-2018-4842?
Medium severity. CVSS v3 base score is 4.8 out of 10.