Auth bypass in Rockwellautomation Powermonitor 1000

CVE-2018-19616

An issue was discovered in Rockwell Automation Allen-Bradley PowerMonitor 1000. An unauthenticated user can add/edit/remove administrators because access control is implemented on the client side via a disabled attribute for a BUTTON element.

Vulnerability class: Broken Authentication

EPSS: 0.303 (98.0th percentile) — read the EPSS interpretation.

CVSS v3 metric

CVSS v3 base score 8.1 (High). Vector: CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H.

Affected products

Weakness classification (CWE)

References

  • cve@mitre.org (US Government Resource, Third Party Advisory, x_refsource_MISC)
  • cve@mitre.org (VDB Entry, Third Party Advisory, x_refsource_MISC)
  • cve@mitre.org (VDB Entry, Third Party Advisory, vdb-entry, x_refsource_BID)
  • cve@mitre.org (VDB Entry, Third Party Advisory, exploit, x_refsource_EXPLOIT-DB)
  • cve@mitre.org (vdb-entry, x_refsource_BID)

Frequently asked questions

What is CVE-2018-19616?
CVE-2018-19616 is a high-severity vulnerability in Rockwellautomation Powermonitor 1000, classified under Improper Authentication. CVSS score: 8.1/10. Published 2018-12-26.
How severe is CVE-2018-19616?
High severity. CVSS v3 base score is 8.1 out of 10.