Resource exhaustion in Rockwellautomation Powerflex 525 Ac Drives Firmware

CVE-2018-19282

Rockwell Automation PowerFlex 525 AC Drives 5.001 and earlier allow remote attackers to cause a denial of service by crashing the Common Industrial Protocol (CIP) network stack. The vulnerability allows the attacker to crash the CIP in a way that it does not accept new connections, but keeps the current connections active, which can prevent legitimate users from recovering control.

Vulnerability class: DoS (Denial of Service)

Published · last modified .

CVSS v3 metric

CVSS v3 base score 9.8 (Critical). Vector: CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H.

EPSS exploit prediction

EPSS 0.056, 93.1th percentile (scored ); unchanged over 30 days. About EPSS.

Affected products

Weakness classification (CWE)

References