Vulnerability in Siemens Simatic S7-400
CVE-2018-16557
A vulnerability has been identified in SIMATIC S7-400 CPU 412-1 DP V7 (All versions), SIMATIC S7-400 CPU 412-2 DP V7 (All versions), SIMATIC S7-400 CPU 414-2 DP V7 (All versions), SIMATIC S7-400 CPU 414-3 DP V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416-2 DP V7 (All versions), SIMATIC S7-400 CPU 416-3 DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416F-2 DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 417-4 DP V7 (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions < V7.0.3), SIMATIC S7-400 H V4.5 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) (All versions < V6.0.9), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-410 CPU family (incl. SIPLUS variants) (All versions < V8.2.1), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions < V7.0.3), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions < V7.0.3), SIPLUS S7-400 CPU 416-3 V7 (All versions), SIPLUS S7-400 CPU 417-4 V7 (All versions). Sending of specially crafted packets to port 102/tcp via Ethernet interface via PROFIBUS or Multi Point Interfaces (MPI) could cause a denial of service condition on affected devices. Flashing with a firmware image may be required to recover the CPU. Successful exploitation requires an attacker to have network access to port 102/tcp via Ethernet interface or to be able to send messages via PROFIBUS or Multi Point Interfaces (MPI) to the device. No user interaction is required. If no access protection is configured, no privileges are required to exploit the security vulnerability. The vulnerability could allow causing a denial of service condition of the core functionality of the CPU, compromising the availability of the system.
EPSS: 0.008 (53.6th percentile) — read the EPSS interpretation.
CVSS v3 metric
CVSS v3 base score 8.2 (High). Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H.
Affected products
- Siemens Simatic_s7-400
- Siemens Simatic S7-400 Cpu 412-1 Dp V7 — versions All versions
- Siemens Simatic S7-400 Cpu 412-2 Dp V7 — versions All versions
- Siemens Simatic S7-400 Cpu 412-2 Pn V7 — versions All versions < V7.0.3
- Siemens Simatic S7-400 Cpu 414-2 Dp V7 — versions All versions
- Siemens Simatic S7-400 Cpu 414-3 Dp V7 — versions All versions
- Siemens Simatic S7-400 Cpu 414-3 Pn/dp V7 — versions All versions < V7.0.3
- Siemens Simatic S7-400 Cpu 414f-3 Pn/dp V7 — versions All versions < V7.0.3
- Siemens Simatic S7-400 Cpu 416-2 Dp V7 — versions All versions
- Siemens Simatic S7-400 Cpu 416-3 Dp V7 — versions All versions
Weakness classification (CWE)
References
- productcert@siemens.com (Vendor Advisory)
Frequently asked questions
- What is CVE-2018-16557?
- CVE-2018-16557 is a high-severity vulnerability in Siemens Simatic S7-400, classified under Improper Verification of Cryptographic Signature. CVSS score: 8.2/10. Published 2018-12-13.
- How severe is CVE-2018-16557?
- High severity. CVSS v3 base score is 8.2 out of 10.