Privilege escalation in Siemens Rox Ii Firmware
CVE-2018-13802
A vulnerability has been identified in ROX II (All versions < V2.12.1). An authenticated attacker with a high-privileged user account access via SSH could circumvent restrictions in place and execute arbitrary operating system commands. Successful exploitation requires that the attacker has network access to the SSH interface in on port 22/tcp. The attacker must be authenticated to exploit the vulnerability. The vulnerability could allow an attacker to execute arbitrary code on the device.
Published · last modified .
CVSS v3 metric
CVSS v3 base score 7.2 (High). Vector: CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H.
EPSS exploit prediction
EPSS 0.036, 89.6th percentile (last changed ); unchanged over 30 days. About EPSS.
Affected products
- Siemens Rox Ii Firmware
- Siemens Ag Rox Ii — versions All versions < V2.12.1
Weakness classification (CWE)
References
- ics-cert.us-cert.gov/advisories/ICSA-18-282-03 (US Government Resource, Third Party Advisory)
- cert-portal.siemens.com/productcert/pdf/ssa-493830.pdf (Vendor Advisory)
- www.securityfocus.com/bid/105545 (Third Party Advisory, VDB Entry, vdb-entry)