Privilege escalation in Siemens Rox Ii
CVE-2018-13802
A vulnerability has been identified in ROX II (All versions < V2.12.1). An authenticated attacker with a high-privileged user account access via SSH could circumvent restrictions in place and execute arbitrary operating system commands. Successful exploitation requires that the attacker has network access to the SSH interface in on port 22/tcp. The attacker must be authenticated to exploit the vulnerability. The vulnerability could allow an attacker to execute arbitrary code on the device.
EPSS: 0.036 (88.2th percentile) — read the EPSS interpretation.
CVSS v3 metric
CVSS v3 base score 7.2 (High). Vector: CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H.
Affected products
- Siemens Rox_ii
- Siemens Rox_ii_firmware
- Siemens Ag Rox Ii — versions All versions < V2.12.1
Weakness classification (CWE)
References
- productcert@siemens.com (US Government Resource, Third Party Advisory, x_refsource_MISC)
- productcert@siemens.com (x_refsource_CONFIRM, Vendor Advisory)
- productcert@siemens.com (VDB Entry, Third Party Advisory, vdb-entry, x_refsource_BID)
Frequently asked questions
- What is CVE-2018-13802?
- CVE-2018-13802 is a high-severity vulnerability in Siemens Rox Ii, classified under CWE-264. CVSS score: 7.2/10. Published 2018-10-10.
- How severe is CVE-2018-13802?
- High severity. CVSS v3 base score is 7.2 out of 10.