Vulnerability in Abb Microscada
CVE-2018-1168
This vulnerability allows local attackers to escalate privileges on vulnerable installations of ABB MicroSCADA 9.3 with FP 1-2-3. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability. The specific flaw exists within the configuration of the access controls for the installed product files. The installation procedure leaves critical files open to manipulation by any authenticated user. An attacker can leverage this vulnerability to escalate privileges to SYSTEM. Was ZDI-CAN-5097.
Published · last modified .
CVSS v3 metric
CVSS v3 base score 7.8 (High). Vector: CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H.
EPSS exploit prediction
EPSS 0.003, 24.5th percentile (scored ); unchanged over 30 days. About EPSS.
Affected products
- Abb Microscada — versions 9.3 with FP 1-2-3
- Hitachienergy Sys600 Firmware — versions 9.0, 9.1, 9.1.5
Weakness classification (CWE)
Public exploits and proof-of-concept code
Also mentioned in 1 other repository (ExpLangcn/FuYao-Go). These reference the CVE in a list, notes or a scanner and are not exploit code for it.
References
- library.e.abb.com/public/7a88a74b12bb492ea138b1f2365d00f6/ABBVU-PGGA-33888_ABB_… (Mitigation, Vendor Advisory)
- zerodayinitiative.com/advisories/ZDI-18-141 (VDB Entry, Third Party Advisory)