Vulnerability in Siemens Automation License Manager
CVE-2018-11456
- CVSS v3
- 5.8 Medium
- Public exploits
- None known
- EPSS
- 0.013 · 70.0th percentile
- Published
- 2018-08-07
A vulnerability has been identified in Automation License Manager 5 (All versions < 5.3.4.4). An attacker with network access to the device could send specially crafted network packets to determine whether or not a network port on another remote system is accessible or not. This allows the attacker to do basic network scanning using the victims machine. Successful exploitation requires a network connection to the affected device. The attacker does not need privileges, no user interaction is required. The impact is limited to determining whether or not a port on a target system is accessible by the affected device.
Published · last modified .
CVSS v3 metric
CVSS v3 base score 5.8 (Medium). Vector: CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:N.
- Attack Vector
- Network
AV:N - Attack Complexity
- Low
AC:L - Privileges Required
- None
PR:N - User Interaction
- None
UI:N - Scope
- Changed
S:C - Confidentiality
- Low
C:L - Integrity
- None
I:N - Availability
- None
A:N
EPSS exploit prediction
EPSS 0.013, 70.0th percentile (last changed ); unchanged over 30 days. About EPSS.
Affected products
- Siemens Automation License Manager
- Siemens Ag Automation License Manager 5 — versions Automation License Manager 5 : All versions < 5.3.4.4
Weakness classification (CWE)
References
- www.securityfocus.com/bid/105114 (Third Party Advisory, VDB Entry, vdb-entry)
- cert-portal.siemens.com/productcert/pdf/ssa-920962.pdf (Vendor Advisory)