CSRF in Siemens Scalance M875 Firmware
CVE-2018-11448
- CVSS v3
- 4.8 Medium
- Public exploits
- None known
- EPSS
- 0.003 · 25.0th percentile
- Published
- 2018-06-26
A vulnerability has been identified in SCALANCE M875 (All versions). The web interface on port 443/tcp could allow a stored Cross-Site Scripting (XSS) attack if an unsuspecting user is tricked into accessing a malicious link. Successful exploitation requires that the attacker has access to the web interface of an affected device. The attacker must be authenticated as administrative user on the web interface. Afterwards, a legitimate user must access the web interface. A successful attack could allow an attacker to execute malicious code in the browser of a legitimate user. At the time of advisory publication no public exploitation of this security vulnerability was known.
Vulnerability class: CSRF (Cross-Site Request Forgery)
Published · last modified .
CVSS v3 metric
CVSS v3 base score 4.8 (Medium). Vector: CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N.
- Attack Vector
- Network
AV:N - Attack Complexity
- Low
AC:L - Privileges Required
- High
PR:H - User Interaction
- Required
UI:R - Scope
- Changed
S:C - Confidentiality
- Low
C:L - Integrity
- Low
I:L - Availability
- None
A:N
EPSS exploit prediction
EPSS 0.003, 25.0th percentile (last changed ); unchanged over 30 days. About EPSS.
Affected products
- Siemens Scalance M875 Firmware
- Siemens Ag Scalance M875 — versions SCALANCE M875 All versions
Weakness classification (CWE)
References