Improper input validation in Siemens 7km Pac Switched Ethernet Profinet Expansion Module Firmware
CVE-2017-9945
- CVSS v3
- 6.5 Medium
- Public exploits
- None known
- EPSS
- 0.005 · 46.2th percentile
- Published
- 2017-08-30
In the Siemens 7KM PAC Switched Ethernet PROFINET expansion module (All versions < V2.1.3), a Denial-of-Service condition could be induced by a specially crafted PROFINET DCP packet sent as a local Ethernet (Layer 2) broadcast. The affected component requires a manual restart via the main device to recover.
Published · last modified .
CVSS v3 metric
CVSS v3 base score 6.5 (Medium). Vector: CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H.
- Attack Vector
- Adjacent
AV:A - Attack Complexity
- Low
AC:L - Privileges Required
- None
PR:N - User Interaction
- None
UI:N - Scope
- Unchanged
S:U - Confidentiality
- None
C:N - Integrity
- None
I:N - Availability
- High
A:H
EPSS exploit prediction
EPSS 0.005, 46.2th percentile (last changed ); unchanged over 30 days. About EPSS.
Affected products
- Siemens 7km Pac Switched Ethernet Profinet Expansion Module Firmware
- Siemens 7km Pac Switched Ethernet Profinet Expansion Module: All Versions < V2.1.3 — versions Siemens 7KM PAC Switched Ethernet PROFINET expansion module: All versions < V2.1.3
Weakness classification (CWE)
References
- www.securityfocus.com/bid/100562 (Third Party Advisory, VDB Entry, vdb-entry)
- www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-771218.pdf (Vendor Advisory)