CVE Explore

RCE in Unicon-Software Elux

CVE-2017-7977

CVSS v3
9.8 Critical
Public exploits
None known
EPSS
0.024 · 84.1th percentile
Published
2017-07-19

The Screensavercc component in eLux RP before 5.5.0 allows attackers to bypass intended configuration restrictions and execute arbitrary commands with root privileges by inserting commands in a local configuration dialog in the control panel.

Vulnerability class: Command Injection (OS Command Injection)

Published · last modified .

CVSS v3 metric

CVSS v3 base score 9.8 (Critical). Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H.

Attack Vector
Network AV:N
Attack Complexity
Low AC:L
Privileges Required
None PR:N
User Interaction
None UI:N
Scope
Unchanged S:U
Confidentiality
High C:H
Integrity
High I:H
Availability
High A:H

EPSS exploit prediction

EPSS 0.024, 84.1th percentile (last changed ); unchanged over 30 days. About EPSS.

Affected products

Weakness classification (CWE)

References