Vulnerability in Rockwell Automation Factorytalk Activation

CVE-2017-6015

Without quotation marks, any whitespace in the file path for Rockwell Automation FactoryTalk Activation version 4.00.02 remains ambiguous, which may allow an attacker to link to or run a malicious executable. This may allow an authorized, but not privileged local user to execute arbitrary code with elevated privileges on the system. CVSS v3 base score: 8.8, CVSS vector string: (AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H). Rockwell Automation has released a new version of FactoryTalk Activation, Version 4.01, which addresses the identified vulnerability. Rockwell Automation recommends upgrading to the latest version of FactoryTalk Activation, Version 4.01 or later.

EPSS: 0.007 (49.9th percentile) — read the EPSS interpretation.

CVSS v3 metric

CVSS v3 base score 7.8 (High). Vector: CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H.

Affected products

Weakness classification (CWE)

References

Frequently asked questions

What is CVE-2017-6015?
CVE-2017-6015 is a high-severity vulnerability in Rockwell Automation Factorytalk Activation, classified under Unquoted Search Path or Element. CVSS score: 7.8/10. Published 2018-05-11.
How severe is CVE-2017-6015?
High severity. CVSS v3 base score is 7.8 out of 10.