Vulnerability in Fujitsu Displayview Click

CVE-2017-3210

Applications developed using the Portrait Display SDK, versions 2.30 through 2.34, default to insecure configurations which allow arbitrary code execution. A number of applications developed using the Portrait Displays SDK do not use secure permissions when running. These applications run the component pdiservice.exe with NT AUTHORITY/SYSTEM permissions. This component is also read/writable by all Authenticated Users. This allows local authenticated attackers to run arbitrary code with SYSTEM privileges. The following applications have been identified by Portrait Displays as affected: Fujitsu DisplayView Click: Version 6.0 and 6.01. The issue was fixed in Version 6.3. Fujitsu DisplayView Click Suite: Version 5. The issue is addressed by patch in Version 5.9. HP Display Assistant: Version 2.1. The issue was fixed in Version 2.11. HP My Display: Version 2.0. The issue was fixed in Version 2.1. Philips Smart Control Premium: Versions 2.23, 2.25. The issue was fixed in Version 2.26.

Published · last modified .

CVSS v3 metric

CVSS v3 base score 7.8 (High). Vector: CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H.

EPSS exploit prediction

EPSS: 0.009 (58.4th percentile), scored .

Very low probability of exploitation in the next 30 days; routine patching cadence is appropriate. 58th percentile — 58.4% of CVEs in the catalogue have a lower EPSS than this one. How to read EPSS.

EPSS trend (30 days)EPSS over the last 30 days for CVE-2017-3210: held from 0.009 to 0.009.

EPSS over last 30 days · oldest: 0.009 · newest: 0.009 · change: 0.000

Affected products

Weakness classification (CWE)

References

Frequently asked questions

What is CVE-2017-3210?
CVE-2017-3210 is a high-severity vulnerability in Fujitsu Displayview Click, classified under Incorrect Default Permissions. CVSS score: 7.8/10. Published 2018-07-24.
How severe is CVE-2017-3210?
High severity. CVSS v3 base score is 7.8 out of 10.