Vulnerability in Mckesson Conserus Workflow Intelligence
CVE-2017-16776
Security researchers discovered an authentication bypass vulnerability in version 2.0.2 of the Conserus Workflow Intelligence application by McKesson Medical Imaging Company, which is now a Change Healthcare company. The attacker must send a malicious HTTP GET request to exploit the vulnerability. The vulnerability allows an attacker to bypass authentication and escalate privileges of valid users. An unauthenticated attacker can exploit the vulnerability and be granted limited access to other accounts. An authenticated attacker can exploit the vulnerability and be granted access reserved for higher privilege users.
EPSS: 0.012 (65.2th percentile) — read the EPSS interpretation.
CVSS v3 metric
CVSS v3 base score 8.1 (High). Vector: CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H.
Affected products
- Mckesson Conserus_workflow_intelligence — versions 2.0.2
- N/a — versions n/a
References
- cve@mitre.org (Exploit, Third Party Advisory, x_refsource_MISC)
Frequently asked questions
- What is CVE-2017-16776?
- CVE-2017-16776 is a high-severity vulnerability in Mckesson Conserus Workflow Intelligence. CVSS score: 8.1/10. Published 2017-12-15.
- How severe is CVE-2017-16776?
- High severity. CVSS v3 base score is 8.1 out of 10.