Vulnerability in Mckesson Conserus Workflow Intelligence

CVE-2017-16776

Security researchers discovered an authentication bypass vulnerability in version 2.0.2 of the Conserus Workflow Intelligence application by McKesson Medical Imaging Company, which is now a Change Healthcare company. The attacker must send a malicious HTTP GET request to exploit the vulnerability. The vulnerability allows an attacker to bypass authentication and escalate privileges of valid users. An unauthenticated attacker can exploit the vulnerability and be granted limited access to other accounts. An authenticated attacker can exploit the vulnerability and be granted access reserved for higher privilege users.

Published · last modified .

CVSS v3 metric

CVSS v3 base score 8.1 (High). Vector: CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H.

EPSS exploit prediction

EPSS: 0.012 (68.1th percentile), scored .

Low probability of exploitation in the next 30 days, but still tracked. 68th percentile — 68.1% of CVEs in the catalogue have a lower EPSS than this one. How to read EPSS.

EPSS trend (30 days)EPSS over the last 30 days for CVE-2017-16776: held from 0.012 to 0.012.

EPSS over last 30 days · oldest: 0.012 · newest: 0.012 · change: 0.000

Affected products

References

Frequently asked questions

What is CVE-2017-16776?
CVE-2017-16776 is a high-severity vulnerability in Mckesson Conserus Workflow Intelligence. CVSS score: 8.1/10. Published 2017-12-15.
How severe is CVE-2017-16776?
High severity. CVSS v3 base score is 8.1 out of 10.