Vulnerability in Philips Intellispace Cardiovascular
CVE-2017-14111
The workstation logging function in Philips IntelliSpace Cardiovascular (ISCV) 2.3.0 and earlier and Xcelera R4.1L1 and earlier records domain authentication credentials, which if accessed allows an attacker to use credentials to access the application, or other user entitlements.
Published · last modified .
CVSS v3 metric
CVSS v3 base score 7.2 (High). Vector: CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H.
EPSS exploit prediction
EPSS 0.022, 82.6th percentile (scored ); unchanged over 30 days. About EPSS.
Affected products
Weakness classification (CWE)
References
- www.usa.philips.com/healthcare/about/customer-support/product-security (Mitigation, Issue Tracking, Vendor Advisory)
- www.securityfocus.com/bid/101850 (Third Party Advisory, VDB Entry, vdb-entry)
- ics-cert.us-cert.gov/advisories/ICSMA-17-318-01 (US Government Resource, Third Party Advisory, Issue Tracking)