Information disclosure in Siemens Logo\!8 Bm Fs-05 Firmware
CVE-2017-12734
- CVSS v3
- 7.5 High
- Public exploits
- None known
- EPSS
- 0.015 · 74.0th percentile
- Published
- 2017-08-30
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V1.81.2). An attacker with network access to the integrated web server on port 80/tcp could obtain the session ID of an active user session. A user must be logged in to the web interface. Siemens recommends to use the integrated webserver on port 80/tcp only in trusted networks.
Published · last modified .
CVSS v3 metric
CVSS v3 base score 7.5 (High). Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N.
- Attack Vector
- Network
AV:N - Attack Complexity
- Low
AC:L - Privileges Required
- None
PR:N - User Interaction
- None
UI:N - Scope
- Unchanged
S:U - Confidentiality
- High
C:H - Integrity
- None
I:N - Availability
- None
A:N
EPSS exploit prediction
EPSS 0.015, 74.0th percentile (last changed ); unchanged over 30 days. About EPSS.
Affected products
- Siemens Logo\!8 Bm Fs-05 Firmware
- Siemens Logo! 8 Bm (Incl. Siplus Variants) — versions All versions < V1.81.2
Weakness classification (CWE)
References
- www.securityfocus.com/bid/100560 (Third Party Advisory, VDB Entry, vdb-entry)
- cert-portal.siemens.com/productcert/pdf/ssa-087240.pdf (Patch, Vendor Advisory)