Information disclosure in Blipcare Wi-Fi Blood Pressure Monitor Firmware

CVE-2017-11578

CVSS v3
5.9 Medium
Public exploits
None known
EPSS
0.020 · 81.6th percentile
Published
2019-07-02

It was discovered as a part of the research on IoT devices in the most recent firmware for Blipcare device that the device allows to connect to web management interface on a non-SSL connection using plain text HTTP protocol. The user uses the web management interface of the device to provide the user's Wi-Fi credentials so that the device can connect to it and have Internet access. This device acts as a Wireless Blood pressure monitor and is used to measure blood pressure levels of a person. This allows an attacker who is connected to the Blipcare's device wireless network to easily sniff these values using a MITM attack.

Vulnerability class: Information Disclosure

Published · last modified .

CVSS v3 metric

CVSS v3 base score 5.9 (Medium). Vector: CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N.

Attack Vector
Network AV:N
Attack Complexity
High AC:H
Privileges Required
None PR:N
User Interaction
None UI:N
Scope
Unchanged S:U
Confidentiality
High C:H
Integrity
None I:N
Availability
None A:N

EPSS exploit prediction

EPSS 0.020, 81.6th percentile (last changed ); unchanged over 30 days. About EPSS.

Affected products

Weakness classification (CWE)

Public exploits and proof-of-concept code

Also mentioned in 1 other repository (ethanhunnt/IoT_vulnerabilities). These reference the CVE in a list, notes or a scanner and are not exploit code for it.