Buffer overflow in Ishekar Endoscope Camera

CVE-2017-10722

Recently it was discovered as a part of the research on IoT devices in the most recent firmware for Shekar Endoscope that the desktop application used to connect to the device suffers from a stack overflow if more than 26 characters are passed to it as the Wi-Fi password. This application is installed on the device and an attacker who can provide the right payload can execute code on the user's system directly. Any breach of this system can allow an attacker to get access to all the data that the user has access too. The application uses a dynamic link library(DLL) called "avilib.dll" which is used by the application to send binary packets to the device that allow to control the device. One such action that the DLL provides is change password in the function "sendchangepass" which allows a user to change the Wi-Fi password on the device. This function calls a sub function "sub_75876EA0" at address 0x7587857C. The function determines which action to execute based on the parameters sent to it. The "sendchangepass" passes the datastring as the second argument which is the password we enter in the textbox and integer 2 as first argument. The rest of the 3 arguments are set to 0. The function "sub_75876EA0" at address 0x75876F19 uses the first argument received and to determine which block to jump to. Since the argument passed is 2, it jumps to 0x7587718C and proceeds from there to address 0x758771C2 which calculates the length of the data string passed as the first parameter.This length and the first argument are then passed to the address 0x7587726F which calls a memmove function which uses a stack address as the destination where the password typed by us is passed as the source and length calculated above is passed as the number of bytes to copy which leads to a stack overflow.

Vulnerability class: Buffer Overflow

Published · last modified .

CVSS v3 metric

CVSS v3 base score 7.8 (High). Vector: CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H.

EPSS exploit prediction

EPSS: 0.007 (52.8th percentile), scored .

Very low probability of exploitation in the next 30 days; routine patching cadence is appropriate. 53rd percentile — 52.8% of CVEs in the catalogue have a lower EPSS than this one. How to read EPSS.

EPSS trend (30 days)EPSS over the last 30 days for CVE-2017-10722: held from 0.007 to 0.007.

EPSS over last 30 days · oldest: 0.007 · newest: 0.007 · change: 0.000

Affected products

Weakness classification (CWE)

Public proof-of-concept exploits

References

Frequently asked questions

What is CVE-2017-10722?
CVE-2017-10722 is a high-severity vulnerability in Ishekar Endoscope Camera, classified under Improper Restriction of Operations within the Bounds of a Memory Buffer. CVSS score: 7.8/10. Published 2019-06-17.
How severe is CVE-2017-10722?
High severity. CVSS v3 base score is 7.8 out of 10.
Is CVE-2017-10722 known to be exploited?
1 public proof-of-concept repositories are indexed. Not currently listed in the CISA KEV catalog.