RCE in Websense Triton

CVE-2015-2746

The network diagnostics tool (CommandLineServlet) in the Appliance Manager command line utility (CLU) in Websense TRITON 7.8.3 and V-Series appliances before 7.8.4 Hotfix 02 allows remote authenticated users to execute arbitrary commands via shell metacharacters in the "second" parameter of a command, as demonstrated by the Destination parameter in the ping command.

Vulnerability class: Command Injection (OS Command Injection)

Published · last modified .

CVSS v2 metric

CVSS v2 base score 6.5 (Medium). Vector: AV:N/AC:L/Au:S/C:P/I:P/A:P. This CVE predates CVSS v3 and has no v3 score from NVD.

EPSS exploit prediction

EPSS: 0.254 (97.9th percentile), scored .

Moderate probability of exploitation in the next 30 days — watch for active exploitation reports. 98th percentile — 97.9% of CVEs in the catalogue have a lower EPSS than this one. How to read EPSS.

EPSS trend (30 days)EPSS over the last 30 days for CVE-2015-2746: held from 0.254 to 0.254.

EPSS over last 30 days · oldest: 0.254 · newest: 0.254 · change: 0.000

Affected products

Weakness classification (CWE)

References