RCE in Websense Triton
CVE-2015-2746
The network diagnostics tool (CommandLineServlet) in the Appliance Manager command line utility (CLU) in Websense TRITON 7.8.3 and V-Series appliances before 7.8.4 Hotfix 02 allows remote authenticated users to execute arbitrary commands via shell metacharacters in the "second" parameter of a command, as demonstrated by the Destination parameter in the ping command.
Vulnerability class: Command Injection (OS Command Injection)
Published · last modified .
CVSS v2 metric
CVSS v2 base score 6.5 (Medium). Vector: AV:N/AC:L/Au:S/C:P/I:P/A:P. This CVE predates CVSS v3 and has no v3 score from NVD.
EPSS exploit prediction
EPSS 0.254, 98.0th percentile (scored ); unchanged over 30 days. About EPSS.
Affected products
- Websense Triton — versions 7.8.3
- Websense V-Series Appliances
Weakness classification (CWE)
References
- www.securify.nl/advisory/SFY20140906/command_injection_vulnerability_in_network… (Exploit)
- packetstormsecurity.com/files/130899/Websense-Appliance-Manager-Command-Injecti… (Exploit)
- www.websense.com/support/article/kbarticle/October-2014-Hotfix-Summary-for-Webs… (Vendor Advisory)
- 20150318 Command injection vulnerability in network diagnostics tool of Websense Appliance Manager (mailing-list)
- www.exploit-db.com/exploits/36423/ (exploit)
- 20150318 Command injection vulnerability in network diagnostics tool of Websense Appliance Manager (mailing-list)