Vulnerability in Sielcosistemi Winlog Lite
CVE-2012-4355
TCPIPS_Story.dll in Sielco Sistemi Winlog Pro SCADA before 2.07.18 and Winlog Lite SCADA before 2.07.18 allows remote attackers to execute arbitrary code via a port-46824 TCP packet with a crafted negative integer after the opcode, triggering incorrect function-pointer processing that can lead to a buffer overflow. NOTE: some of these details are obtained from third party information. NOTE: this vulnerability exists because of an incomplete fix for CVE-2012-4354.
Published · last modified .
CVSS v2 metric
CVSS v2 base score 9.3 (High). Vector: AV:N/AC:M/Au:N/C:C/I:C/A:C. This CVE predates CVSS v3 and has no v3 score from NVD.
EPSS exploit prediction
EPSS: 0.082 (94.7th percentile), scored .
Low probability of exploitation in the next 30 days, but still tracked. 95th percentile — 94.7% of CVEs in the catalogue have a lower EPSS than this one. How to read EPSS.
EPSS over last 30 days · oldest: 0.082 · newest: 0.082 · change: 0.000
Affected products
- Sielcosistemi Winlog Lite — versions 2.06.00, 2.06.03, 2.06.04
- Sielcosistemi Winlog Pro — versions 2.06.00, 2.06.03, 2.06.04
Weakness classification (CWE)
References
- aluigi.org/adv/winlog_2-adv.txt (Exploit)
- www.us-cert.gov/control_systems/pdf/ICSA-12-213-01.pdf (US Government Resource)
- secunia.com/advisories/49395 (Vendor Advisory, third-party-advisory)
- www.sielcosistemi.com/en/news/index.html