Buffer overflow in Siemens Scalance S602
CVE-2012-1800
Stack-based buffer overflow in the Profinet DCP protocol implementation on the Siemens Scalance S Security Module firewall S602 V2, S612 V2, and S613 V2 with firmware before 2.3.0.3 allows remote attackers to cause a denial of service (device outage) or possibly execute arbitrary code via a crafted DCP frame.
Vulnerability class: Buffer Overflow
Published · last modified .
CVSS v2 metric
CVSS v2 base score 6.1 (Medium). Vector: AV:A/AC:L/Au:N/C:N/I:N/A:C. This CVE predates CVSS v3 and has no v3 score from NVD.
EPSS exploit prediction
EPSS: 0.016 (74.8th percentile), scored .
Low probability of exploitation in the next 30 days, but still tracked. 75th percentile — 74.8% of CVEs in the catalogue have a lower EPSS than this one. How to read EPSS.
EPSS over last 30 days · oldest: 0.016 · newest: 0.016 · change: 0.000
Affected products
- Siemens Scalance S602 — versions v2
- Siemens Scalance S612 — versions v2
- Siemens Scalance S613 — versions v2
- Siemens Scalance S Firmware — versions 2.1.0, 2.2.0
Weakness classification (CWE)
References
- support.automation.siemens.com/WW/view/en/59869684
- www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_… (Vendor Advisory)
- www.us-cert.gov/control_systems/pdf/ICSA-12-102-05.pdf (US Government Resource)
- osvdb.org/81034 (vdb-entry)