Path Traversal in Siemens Simatic Hmi Panels

CVE-2011-4878

Directory traversal vulnerability in miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to read arbitrary files via a ..%5c (dot dot backslash) in a URI.

Vulnerability class: Path Traversal (Directory Traversal)

Published · last modified .

CVSS v2 metric

CVSS v2 base score 7.8 (High). Vector: AV:N/AC:L/Au:N/C:C/I:N/A:N. This CVE predates CVSS v3 and has no v3 score from NVD.

EPSS exploit prediction

EPSS: 0.111 (95.8th percentile), scored .

Moderate probability of exploitation in the next 30 days — watch for active exploitation reports. 96th percentile — 95.8% of CVEs in the catalogue have a lower EPSS than this one. How to read EPSS.

EPSS trend (30 days)EPSS over the last 30 days for CVE-2011-4878: fell from 0.121 to 0.111.

EPSS over last 30 days · oldest: 0.121 · newest: 0.111 · change: -0.010

Affected products

Weakness classification (CWE)

References