Vulnerability in HP Mercury Quality Center
CVE-2007-5289
HP Mercury Quality Center (QC) 9.2 and earlier, and possibly TestDirector, relies on cached client-side scripts to implement "workflow" and decisions about the "capability" of a user, which allows remote attackers to execute arbitrary code via crafted use of the Open Test Architecture (OTA) API, as demonstrated by modifying (1) common.tds, (2) defects.tds, (3) manrun.tds, (4) req.tds, (5) testlab.tds, or (6) testplan.tds in %tmp%\TD_80, and then setting the file's properties to read-only.
Published · last modified .
CVSS v2 metric
CVSS v2 base score 7.6 (High). Vector: AV:N/AC:H/Au:N/C:C/I:C/A:C. This CVE predates CVSS v3 and has no v3 score from NVD.
EPSS exploit prediction
EPSS 0.087, 95.2th percentile (scored ); unchanged over 30 days. About EPSS.
Affected products
- HP Mercury Quality Center — versions 8.0, 8.2, 9.0
- HP Testdirector
Weakness classification (CWE)
References
- secunia.com/advisories/34046 (third-party-advisory)
- 20090223 HP Quality Center vulnerability (mailing-list)
- www.securityfocus.com/bid/33854 (vdb-entry)
- secunia.com/advisories/34015 (third-party-advisory, Vendor Advisory)
- hpqualitycenter-workflowscripts-sec-bypass(48860) (vdb-entry)
- VU#898865 (US Government Resource, third-party-advisory)
- 20090224 Re: HP Quality Center vulnerability (mailing-list)
- blogs.exposit.co.uk/2009/02/23/vulnerability-in-quality-center/